Actions for Test of a cryogenic helium pump [electronic resource].
Test of a cryogenic helium pump [electronic resource].
- Published
- Oak Ridge, Tenn. : Oak Ridge National Laboratory, 1981.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- Pages: 7 : digital, PDF file
- Additional Creators
- Oak Ridge National Laboratory and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- The design of a cryogenic helium pump for circulating liquid helium in a magnet and the design of a test loop for measuring the pump performance in terms of mass flow vs pump head at various pump speeds are described. A commercial cryogenic helium pump was tested successfully. Despite flaws in the demountable connections, the piston pump itself has performed satisfactorily. A helium pump of this type is suitable for the use of flowing supercritical helium through Internally Cooled Superconductor (ICS) magnets. It has pumped supercritical helium up to 7.5 atm with a pump head up to 2.8 atm. The maximum mass flow rate obtained was about 16 g/s. Performance of the pump was degraded at lower pumping speeds. (LCL)
- Report Numbers
- E 1.99:conf-810835-6
conf-810835-6 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/01/1981.
"conf-810835-6"
"DE81028629"
1981 cryogenic engineering conference, San Diego, CA, USA, 10 Aug 1981.
Miller, J.R.; Lue, J.W.; Herz, W.; Walstrom, P.L. - Funding Information
- W-7405-ENG-26
View MARC record | catkey: 13828697