Actions for Slag characterization and removal using pulse detonation for coal gasification. Quarterly report, October 1--December 31, 1996 [electronic resource].
Slag characterization and removal using pulse detonation for coal gasification. Quarterly report, October 1--December 31, 1996 [electronic resource].
Published
Washington, D.C. : United States. Dept. of Energy, 1997. Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy.
This report summarizes the costs associated with ash fouling and its removal from the heat exchanger of the Sherburne Co. plant`s 800 MW unit. The lead heat exchanger in the convective pass takes the brunt of the ash accumulation. This study concluded that for the amount of money used one cleaning cycle, 33 pulse detonation units could be purchased.
Published through SciTech Connect. 12/31/1997. "doe/mt/95010--09" "DE98058009" Zhou, J.; Huque, Z.; Mei, D.; Biney, P.O. Prairie View A and M Univ., Dept. of Mechanical Engineering, TX (United States)