- A laboratory to evaluate the performance and cycle life of flowing electrolyte battery systems has been established at Sandia National Laboratories. Four unique flow batteries are being tested in the laboratory using a four-variable two-level factorial experimental plan. Two Exxon zinc bromine batteries and one Gould zinc bromine battery are under test. One NASA Redox battery is on test. This paper describes results obtained to date from the test program. Cycle history, efficiency values, and general performance observations for these batteries are reported. The factorial test program and available statistical results are also discussed.