- An evaluation has been made of the corrosiveness of selected wet residential building thermal insulation materials in contact with low carbon steel. Investigations were conducted both in wet insulations and in filtered leachates from insulations derived from thirteen cellulosic, three mineral fiber and four foam products. Potentiodynamic polarization measurements are reported from which the overall corrosion response was assessed and then the techniques of Tafel and polarization resistance analysis applied to estimate corrosion rates. Corrosion rates were also estimated electrochemically using a direct reading instrument which performs the rate calculation based on the polarization resistance principle. Direct determinations of corrosion rate were based on weight loss measurements.
- Report Numbers
- E 1.99:ornl/sub--90-sf204/1
ornl/sub--90-sf204/1 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
10/01/1991.
"ornl/sub--90-sf204/1"
"DE92004905"
Stansbury, E.E. - Type of Report and Period Covered Note