Actions for Analysis of a micro-scale pump which uses controlled acoustic streaming for fluid locomotion [electronic resource].
Analysis of a micro-scale pump which uses controlled acoustic streaming for fluid locomotion [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy, 1998.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- 19 pages : digital, PDF file
- Additional Creators
- Sandia National Laboratories, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- In this report the analysis of a micro-scale pump is described. This micro-pump uses active control to produce a distributed body force in a fluid micro-channel. The desired effect of this body force is to drive fluid through the channel. Limitations, assumptions, and design parameters are discussed. The mathematical analysis of pump dynamics is explained in detail. A perturbation analysis is used on the equations of mass, momentum and state to produce equations of motion for first and second order effects. The first order effects are described by linear wave motion in the fluid and are found by using integral equation methods. The second order effects are driven by body forces resulting from first order effects. Thus, by controlling the production of wave motion in the channel, second order excitation can also be controlled. This report is all theory and therefore needs experimental validation. Although many of the assumptions used in this report have been used elsewhere in the literature and have been found to be sufficient, there are many aspects of the problem which have been left unresolved. In particular, flow separation in the fluid channel is a critical problem. If the fluid does not separate, pumping will occur through the channel, however, if internal or external forces are not sufficient to stop separation, this type of pump will not function.
- Report Numbers
- E 1.99:sand--98-0207
sand--98-0207 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/01/1998.
"sand--98-0207"
"DE98002762"
Dohner, J.L. - Funding Information
- AC04-94AL85000
View MARC record | catkey: 14108564