- Summary:
- An experimental program has been completed which evaluated the effect of a flow obstruction in a heated channel on the onset of flow instability (OBI). The test channel was rectangular (80 × 3 mm), heated on one surface, and equipped with view ports. Tests were conducted in a flow controlled mode at heat fluxes of 370 kW/M², and 610 kW/m². Direct comparisons were made between the demand curve minimum for the unobstructed channel and a channel equipped with a 2.07 mm wide rib that was parallel to the flow and in contact with the heated surface. Data at OFI is presented in the nondimensional terms Of Q{sub ratio} (ratio of heat flux applied to heat flux required to achieve saturated liquid conditions at the exit), and the local Stanton number at the channel exit for each channel arrangement. The Q{sub ratio} and Stanton number values for the unobstructed channel and the rib equipped channel are then compared to produce an estimate of the rib effect.
- Report Numbers:
- E 1.99:wsrc--ms-93-479
wsrc--ms-93-479 - Subject(s):
- Other Subject(s):
- Dissertation Note:
- Thesis submitted to the University of South Carolina, Columbia, SC.; TH: Thesis (Ph.D.); PBD: 9 Sep 1993
- Note:
- Published through SciTech Connect.
09/09/1993.
"wsrc--ms-93-479"
"DE93041146"
Coutts, D.A. - Funding Information:
- AC09-89SR18035
View MARC record | catkey: 14115640