An investigation of temperature measurement methods in nuclear power plant reactor pressure vessel annealing [electronic resource].
- Published:
- Washington, D.C. : United States. Dept. of Energy, 1996.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description:
- 155 pages : digital, PDF file
- Additional Creators:
- Sandia National Laboratories, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Summary:
- The objective of this project was to provide an assessment of several methods by which the temperature of a commercial nuclear power plant reactor pressure vessel (RPV) could be measured during an annealing process. This project was a coordinated effort between DOE`s Office of Nuclear Energy, Science and Technology; DOE`s Light Water Reactor Technology Center at Sandia National Laboratories; and the Electric Power Research Institute`s Non- Destructive Evaluation Center. Ball- thermocouple probes similar to those described in NUREG/CR-5760, spring-loaded, metal- sheathed thermocouple probes, and 1778 air- suspended thermocouples were investigated in experiments that heated a section of an RPV wall to simulate a thermal annealing treatment. A parametric study of ball material, emissivity, thermal conductivity, and thermocouple function locations was conducted. Also investigated was a sheathed thermocouple failure mode known as shunting (electrical breakdown of insulation separating the thermocouple wires). Large errors were found between the temperature as measured by the probes and the true RPV wall temperature during heat-up and cool-down. At the annealing soak temperature, in this case 454°C [850`F], all sensors measured the same temperature within about ±5% (23.6°C [42.5°F]). Because of these errors, actual RPV wall heating and cooling rates differed from those prescribed (by up to 29%). Shunting does not appear to be a problem under these conditions. The large temperature measurement errors led to the development of a thermal model that predicts the RPV wall temperature from the temperature of a ball- probe. Comparisons between the model and the experimental data for ball-probes indicate that the model could be a useful tool in predicting the actual RPV temperature based on the indicated ball- probe temperature. The model does not predict the temperature as well for the spring-loaded and air suspended probes.
- Report Numbers:
- E 1.99:sand--96-1179
sand--96-1179 - Subject(s):
- Other Subject(s):
- Note:
- Published through SciTech Connect.
05/01/1996.
"sand--96-1179"
"DE96011531"
Gill, W.; Schulze, D.H.; Nakos, J.T.; Acton, R.U.; Sais, D.J. - Funding Information:
- AC04-94AL85000
View MARC record | catkey: 14364155