LOFT CIS analysis line 2''-LS-120-AB outside containment penetration S-1A [electronic resource].
- Published:
- Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1978.
- Physical Description:
- Pages: 50 : digital, PDF file
- Additional Creators:
- United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Summary:
- Line 2''-LS-120-AB outside containment penetration S-1A was analyzed to ASME Section III, Subsection NC (Class 2) criteria. The line is part of the LOFT Containment Isolation System. The model considered the line from the penetration outward through the second isolation valve. Results of the analysis show that this section of the line meets Class 2 requirements without modification.
- Report Numbers:
- E 1.99:ltr-137-1
ltr-137-1 - Subject(s):
- Other Subject(s):
- Note:
- Published through SciTech Connect.
08/18/1978.
"ltr-137-1"
Pierce, A.T.
Idaho National Engineering Lab., Idaho Falls (USA) - Funding Information:
- EY-76-C-07-1570