Testing to evaluate synergistic effects from LOCA environments. Test IX. Simultaneous mode; cables, splice assemblies, and electrical insulation samples [electronic resource].
- Published
- Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1978.
- Physical Description
- Pages: 101 : digital, PDF file
- Additional Creators
- United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- This test was conducted to complement Test VIII which was a sequential test of cables, cable splices, and insulation samples. In this test, the generic LOCA environments (radiation, temperature, pressure, chemical spray) were simulated and simultaneously applied to the test items. There were no failures of any assemblies and all were able to function at rated current and voltage throughout the entire test. An additional parameter, dissipation factor, was monitored in this test and when used in conjunction with capacitance, provided a better indication of insulation degradation.