LOFT emergency core coolant thermal analysis Class I review [electronic resource].
- Published:
- Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1978.
- Physical Description:
- Pages: 20 : digital, PDF file
- Additional Creators:
- United States. Department of Energy. Office of Scientific and Technical Information
- Access Online:
- www.osti.gov
- Summary:
- The LOFT Emergency Core Coolant Piping Thermal Analysis was checked to insure that the calculations made would conservatively satisfy the requirements in the LOFT technical specifications. Some of the boundary conditions used have not been shown to be conservative and require review and possible re-analysis. One of the thermal models used could not be clearly related to a specific part of the piping geometry and requires further explanation. The remainder of the models, the use of the SIMIR code and the other boundary conditions appear conservative and reflect normal thermal analysis methodology and practice. However, the use of constant, rather than temperature varying, thermal properties for some materials may introduce a slight error in these analyses.
- Subject(s):
- Note:
- Published through SciTech Connect., 02/03/1978., "ltr-113-48", " re-a-77-123", Kinnaman, T.L., and Idaho National Engineering Lab., Idaho Falls (USA)
- Funding Information:
- EY-76-C-07-1570
View MARC record | catkey: 14370156