Actions for Final Report - Gas Retention and Release Tests Supporting the Concentrate Receipt Vessel (CRV-VSL-00002A
Final Report - Gas Retention and Release Tests Supporting the Concentrate Receipt Vessel (CRV-VSL-00002A/2B) Configuration [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy, 2004.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- vp : digital, PDF file
- Additional Creators
- United States. Department of Energy. Savannah River Site, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- Gas Retention and Release (GR and R) tests were performed in the scaled Concentrate Receipt Vessel (CRV) Test Stand at the Savannah River National Laboratory to validate the capability of candidate Hybrid-Mixing systems for the CRV to safely release hydrogen during normal and upset conditions. Hydrogen is generated in the radioactive waste as a result of natural and plant processes and must not be allowed to accumulate above flammability limits. Two types of tests were conducted. Gas holdup tests determined the steady state amount of gas accumulated in the simulant under normal PJM only or PJM plus sparging conditions. Gas release tests determined what operating conditions are necessary to fully release gas after a steady state gas fraction of 4 per cent tank volume or more was reached in the simulant.
- Report Numbers
- E 1.99:wsrc-tr-2004-00399, rev. 0srnl-rpp-2004-00062, rev 0
wsrc-tr-2004-00399, rev. 0srnl-rpp-2004-00062, rev 0 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
09/01/2004.
"wsrc-tr-2004-00399, rev. 0srnl-rpp-2004-00062, rev 0"
GUERRERO, HECTOR. - Type of Report and Period Covered Note
- Topical;
- Funding Information
- AC09-96SR18500
View MARC record | catkey: 14391009