Actions for Response Calculations of the CdZnTe Detector Using EGS4 [electronic resource].
Response Calculations of the CdZnTe Detector Using EGS4 [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy. Office of Energy Research, 2000.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- 64 kilobytes pages : digital, PDF file
- Additional Creators
- Stanford Linear Accelerator Center, United States. Department of Energy. Office of Energy Research, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- The spectral response of a CdZnTe semiconductor detector has been calculated with the EGS4 Code System. The latest low-energy photon production and transport routines developed at KEK, which consider the K and L shell fluorescent photon production in compounds, bound Compton scattering, Doppler broadening, etc., were included in the EGS4 code. The calculations of the CdZnTe detector also took into account the collection efficiency of the produced electron-hole pairs (described by Hecht equation) and the modification on spectral peaks due to both the Fano factor and electronic-noise broadening. The calculated results are compared with measurements made with encapsulated ²⁴¹Am and ¹³⁷Cs disk sources. It was found that, by trying various mobility-lifetime values for holes, the calculated spectral response still did not have perfect agreement with measurements.
- Report Numbers
- E 1.99:slac-pub-8606
slac-pub-8606 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
09/08/2000.
"slac-pub-8606"
Liu, James C. - Type of Report and Period Covered Note
- Topical;
- Funding Information
- AC03-76SF00515