1976 intercomparison of personnel dosimeters [electronic resource].
- Published
- Oak Ridge, Tenn. : Oak Ridge National Laboratory, 1976.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- Pages: 25 : digital, PDF file
- Additional Creators
- Oak Ridge National Laboratory and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- The second Personnel Dosimeter Intercomparison Study (PDIS) was conducted at Oak Ridge National Laboratory's DOSAR Facility during the period February 18-19, 1976. Eleven independent organizations participated in an intercomparison of neutron and gamma-ray dosimeters used for routine personnel dosimetry. The dosimeters, which were shipped to the DOSAR Facility, were exposed at the Health Physics Research Reactor to one of three ''standardized'' radiation fields which have been used for the past several years for intercomparing nuclear accident dosimeters. The results of PDIS reveal that estimates of dose equivalent vary over a wide range. For a given radiation field these dose estimates may vary by more than a factor of 2, indicating the need for continued evaluation of the response of personnel dosimeters used in mixed fields of neutron and gamma radiation.
- Report Numbers
- E 1.99:ornl/tm-5672
ornl/tm-5672 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
12/01/1976.
"ornl/tm-5672"
Dickson, H.W.; Gilley, L.W.; Christian, D.J. - Funding Information
- W-7405-ENG-26
View MARC record | catkey: 14401775