- Summary
- The Expert Panel Oversight Committee (EPOC) has been overseeing the implementation of selected parts of Recommendation III of the final report, Expert Panel workshop for Hanford Site Double-Shell Tank Waste Chemistry Optimization, RPP-RPT-22126. Recommendation III provided four specific requirements necessary for Panel approval of a proposal to revise the chemistry control limits for the Double-Shell Tanks (DSTs). One of the more significant requirements was successful performance of an accelerated stress corrosion cracking (SCC) experimental program. This testing program has evaluated the optimization of the chemistry controls to prevent corrosion in the interstitial liquid and supernatant regions of the DSTs.
- Report Numbers
- E 1.99:rpp-asmt-39508 rev 0
rpp-asmt-39508 rev 0 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/08/2009.
"rpp-asmt-39508 rev 0"
BOOMER KD. - Funding Information
- DE-AC27-08RV14800