Effect of Insolation Boundary Conditions on Type B Package Internal Temperatures [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy, 2002.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- 7p : digital, PDF file
- Additional Creators
- Lawrence Berkeley National Laboratory, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- The prescription of the initial conditions and the final conditions for a thermal accident for Type B packages are different for differing regulations. This paper presents an analytical method for estimating the effect of the boundary conditions on post-fire peak internal package temperatures. Results are given for several boundary conditions for a Type B drum-type package.
- Report Numbers
- E 1.99:ucrl-jc-148654
ucrl-jc-148654 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
05/30/2002.
"ucrl-jc-148654"
2002 American Society of Mechanical Engineers Pressure Vessels and Piping Conference, Vancouver, Canada, Aug 04 - Aug 08, 2002.
Hovingh, J; Shah, VL. - Funding Information
- W-7405-ENG-48
View MARC record | catkey: 14410566