- The DWPF Salt Cell Vent Condenser (SCVC) includes a High Efficiency Mist Eliminator (HEME) designed to remove mercury aerosols that may form in the Precipitate Reactor (PR) condenser. The Savannah River Technology Center was requested by DWPF to make a performance assesssment of a prototypic HEME element in the vent system of the Precipitate Hydrolysis Experimental Facility at TNX.