Working group session report [electronic resource] : Neutron beam line shielding
- Published
- Washington, D.C. : United States. Dept. of Energy, 2001.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- 4 pages : digital, PDF file
- Additional Creators
- Los Alamos National Laboratory, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- We have examined the differences between a 2-D model and a 3-D model for designing the beam-line shield for the HIPPO instrument at the Lujan Center at the Los Alamos National Laboratory. We have calculated the total (neutron and gamma ray) dose equivalent rate coming out of the personal access ports from the HIPPO instrument experiment cave. In order to answer this question, we have investigated two possible worst-case scenarios: (a) failure of the T₀-chopper and no sample at the sample position; and (b) failure of the T₀-chopper with a thick sample (a piece of Inconel-718, 10 cm diam by 30 cm long) at the sample position.
- Report Numbers
- E 1.99:la-ur-01-0418
la-ur-01-0418 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/01/2001.
"la-ur-01-0418"
"ICANS-XV: 15th Meeting of the International Collaboration on Advanced Neutron Sources, November 6-9, 2000, Tsukuba, Japan".
Russell, G. J.; Ikedo, Y.
View MARC record | catkey: 14448591