The author presents his experience in manufacturing IGSCC realistic defects, mainly in INCONEL 600 MA Steam Generator Tubes. From that experience he extracts some knowledge about this cracking (influence of chemistry in the environment, stress state, crack growth rate, and occurrence in laboratory condition of break before leak).
Report Numbers
E 1.99:nureg/cp--0154 E 1.99: anl--96/14 E 1.99:nea/cnra/r--(96)1 E 1.99:conf-9510423-- conf-9510423-- nea/cnra/r--(96)1 anl--96/14 nureg/cp--0154
Published through SciTech Connect. 02/01/1997. "nureg/cp--0154" " anl--96/14" "nea/cnra/r--(96)1" "conf-9510423--" "TI97004312" CNRA/CSNI workshop on steam generator tube integrity in nuclear power plants, Oak Brook, IL (United States), 30 Oct - 2 Nov 1995. Veron, P.