Evaluation of silver mordenite for radioiodine retention at the PUREX Process Facility Modification [electronic resource].
- Published
- Richland, Wash. : Pacific Northwest Laboratory, 1987.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- Pages: 58 : digital, PDF file
- Additional Creators
- Pacific Northwest Laboratory and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- To determine the bed-loading capacities and the effluent iodine concentrations at normal, off-normal, and standby conditions, PNL performed a series of statistically designed parametric tests using a bed of AgZ 12 cm long x 1 cm diameter. In addition, tests were performed to determine the effect of bed length, the effect of a second bed, the effect of extended standby conditions, and the efficiency of hydrogen-reduced AgZ (Ag/sup 0/Z). Results of these experiments are presented in this report.
- Report Numbers
- E 1.99:pnl-6261
pnl-6261 - Subject(s)
- Other Subject(s)
- Iodine
- Removal
- Purex Process
- Off-Gas Systems
- Silver Compounds
- Sorptive Properties
- Zeolites
- Adsorbents
- Head End Processes
- Nitrogen Oxides
- Reduction
- Chalcogenides
- Chemical Reactions
- Elements
- Halogens
- Inorganic Ion Exchangers
- Ion Exchange Materials
- Materials
- Minerals
- Nitrogen Compounds
- Nonmetals
- Oxides
- Oxygen Compounds
- Reprocessing
- Separation Processes
- Surface Properties
- Transition Element Compounds
- Note
- Published through SciTech Connect.
07/01/1987.
"pnl-6261"
"DE87012500"
Burger, L.L.; Scheele, R.D. - Funding Information
- AC06-76RL01830
View MARC record | catkey: 14666301