Comparison of Tevatron C0 and F0 Lambertson beam impedance [electronic resource].
- Published:
- Washington, D.C. : United States. Dept. of Energy. Office of Energy Research, 2003.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description:
- 1,013 Kilobytes pages : digital, PDF file
- Additional Creators:
- Fermi National Accelerator Laboratory, United States. Department of Energy. Office of Energy Research, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Summary:
- Both the longitudinal and transverse beam impedance measurements for the Tevatron C0 and F0 lambertsons are presented. The C0 lambertsons were designed for circulating beam to travel through the 1 inch high by 6 inch wide field region. In the F0 lambertsons, circulating beam passes through the 2.5 inch high by 4 in ch wide field free region. The more recently designed F0 lambertsons have significantly less impedance than the older C0 lambertsons. Transverse impedance scales as one over the diameter of the aperture cubed. The three C0 style lambertsons were recently removed from the Tevatron. Four of the F0 lambertsons remain. Nine of the F0 style lambertsons are in the Main Injector and three more are required for Numi.
- Report Numbers:
- E 1.99:fermilab-tm-2205
fermilab-tm-2205 - Subject(s):
- Other Subject(s):
- Note:
- Published through SciTech Connect.
04/11/2003.
"fermilab-tm-2205"
James L Crisp and Brian Fellenz. - Type of Report and Period Covered Note:
- Topical;
- Funding Information:
- AC02-76CH03000
View MARC record | catkey: 14679271