Actions for CEBAF cryogenic system [electronic resource].
CEBAF cryogenic system [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy, 1995.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- 7 pages : digital, PDF file
- Additional Creators
- United States. Department of Energy and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- The CEBAF cryogenic system consists of 3 refrigeration systems: Cryogenic Test Facility (CTF), Central Helium Liquefier (CHL), and End Station Refrigerator (ESR). CHL is the main cryogenic system for CEBAF, consisting of a 4.8 kW, 2.0 K refrigerator and transfer line system to supply 2.0 K and 12 kW of 50 K shield refrigeration for the Linac cavity cryostats and 10 g/s of liquid for the end stations. This paper describes the 9-year effort to commission these systems, concentrating on CHL with the cold compressors. The cold compressors are a cold vacuum pump with an inlet temperature of 3 K which use magnetic bearings, thereby eliminating the possibility of air leaks into the subatmospheric He.
- Report Numbers
- E 1.99:doe/er/40150--358
E 1.99: cebaf-pr--95-040
E 1.99:conf-950512--377
conf-950512--377
cebaf-pr--95-040
doe/er/40150--358 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
12/31/1995.
"doe/er/40150--358"
" cebaf-pr--95-040"
"conf-950512--377"
"DE96013340"
16. Institute of Electrical and Electronic Engineers (IEEE) particle accelerator conference, Dallas, TX (United States), 1-5 May 1995.
CEBAF, Newport News, VA (United States) - Funding Information
- AC05-84ER40150
View MARC record | catkey: 14687609