OVERVIEW OF THE RHIC INSERTION REGION, SEXTUPOLE, AND SNAKE POWER SUPPLY SYSTEMS [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy. Office of Energy Research, 2001.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- 3 pages : digital, PDF file
- Additional Creators
- Brookhaven National Laboratory, United States. Department of Energy. Office of Energy Research, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- The Relativistic Heavy Ion Collider (RHIC) was commissioned in 1999 and 2000. RHIC requires power supplies to supply currents to highly inductive superconducting magnets. The RHIC Insertion Region (IR) contains many shunt power supplies to trim the current of different magnet elements in a large superconducting magnet circuit. There are a total of 237 Insertion Region power supplies in both RHIC rings. RHIC also requires sextupole power supplies. One sextupole power supply is connected across 12 sextupole magnets. There are a total of 24 sextupole power supplies in both rings. Snake magnets are also a part of the RHIC ring, and these snake magnets also require power supplies. There shall be a total of 24 snake power supplies in both rings. Power supply technology, connections, control systems and interfacing with the Quench Protection System will be presented.
- Report Numbers
- E 1.99:bnl--68075
E 1.99: ka0201
ka0201
bnl--68075 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
06/18/2001.
"bnl--68075"
" ka0201"
"KA0201"
PARTICLE ACCELERATOR CONFERENCE 2001, CHICAGO, IL (US), 06/18/2001--06/22/2001.
BRUNO,D.; GANETIS,G.; SANDBERG,J.; ENG,W.; LAMBIASE,R.F. - Funding Information
- AC02-98CH10886
AD002ADOP