Radiation measurements during cavities conditioning on APS RF test stand [electronic resource].
Published
Washington, D.C. : United States. Dept. of Energy, 1993. Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy.
In order to determine the shielding structure around the Advanced Photon Source (APS) synchrotron and storage ring RF stations, the X-ray radiation has been measured in the near field and far field regions of the RF cavities during the normal conditioning process. Two cavity types, a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity, are used on the APS and are conditioned in the RF test stand. Vacuum measurements are also taken on a prototype 352-MHz single-cell cavity and a 352-MHz five-cell cavity. The data will be compared with data on the five-cell cavities from CERN.
Report Numbers
E 1.99:anl/asd/cp--78345 E 1.99: conf-930511--311 conf-930511--311 anl/asd/cp--78345