Stochastic cooling with a double rf system [electronic resource].
- Published:
- Washington, D.C. : United States. Dept. of Energy, 1992.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description:
- 3 pages : digital, PDF file
- Additional Creators:
- Brookhaven National Laboratory
United States. Department of Energy
United States. Department of Energy. Office of Scientific and Technical Information - Access Online:
- www.osti.gov
- Summary:
- Stochastic cooling for a bunched beam of hadrons stored in an accelerator with a double rf system of two different frequencies has been investigated. The double rf system broadens the spread in synchrotron-oscillation frequency of the particles when they mostly oscillate near the center of the rf bucket. Compared with the ease of a single rf system, the reduction rates of the bunch dimensions are significantly increased. When the rf voltage is raised, the reduction rate, instead of decreasing linearly, now is independent of the ratio of the bunch area to the bucket area. On the other hand, the spread in synchrotron-oscillation frequency becomes small with the double rf system, if the longitudinal oscillation amplitudes of the particles are comparable to the dimension of the rf bucket. Consequently, stochastic cooling is less effective when the bunch area is close to the bucket area.
- Subject(s):
- Note:
- Published through SciTech Connect.
05/01/1992.
"bnl--46684"
" conf-920315--29"
"DE92013032"
EPAC 92: 3. European particle accelerator conference: accelerators for special applications,Berlin (Germany),24-28 Mar 1992.
Wei, Jie. - Funding Information:
- AC02-76CH00016