- Summary
- Two spectrometers, one on each extraction line of the SLC, have been installed to momentum analyse each SLC beam pulse and determine the electron and positron beam energies. A method of determining and monitoring the absolute magnetic field strength for these dipoles has been developed. A total error on the magnetic field integral of δ∫Bdl/∫Bdl = 1 × 10{sup −4} has been achieved. The field integral can be monitored continuously during SLC beam operation using radiation hardened equipment. The laboratory field mapping techniques and the field monitoring methods are described. 6 refs., 4 figs., 5 tabs.