- Two spectrometers, one on each extraction line of the SLC, have been installed to momentum analyse each SLC beam pulse and determine the electron and positron beam energies. A method of determining and monitoring the absolute magnetic field strength for these dipoles has been developed. A total error on the magnetic field integral of δ∫Bdl/∫Bdl = 1 × 10{sup −4} has been achieved. The field integral can be monitored continuously during SLC beam operation using radiation hardened equipment. The laboratory field mapping techniques and the field monitoring methods are described. 6 refs., 4 figs., 5 tabs.
- Subject(s):
- Note:
- Published through SciTech Connect.
03/01/1989.
"slac-pub-4908"
" lbl--26956"
" conf-890335--103"
"DE89011366"
1989 IEEE particle accelerator conference, Chicago, IL (United States), 20-23 Mar 1989.
Watson, S.; Levi, M.; Nash, J. - Funding Information:
- AC03-76SF00515
View MARC record | catkey: 14696580