Performance of the LAMPF particle separator [electronic resource].
Published
Los Alamos, N.M. : Los Alamos Scientific Laboratory, 1977. Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy.
The electrostatic beam separator in the EPICS channel at LAMPF is now nearly fully operational. Improvements to the high voltage transmission system and the electronic controls as well as a higher quality channel vacuum have allowed the unit to be operated at its design field strengths. The bias electrode has proven to be useful in reducing ion-exchange currents and associated electrode heating. The detachable shielding and other apparatus for removing the separator from the activated channel was perfected and its application is described.
Report Numbers
E 1.99:la-ur-77-545 E 1.99: conf-770313-8 conf-770313-8 la-ur-77-545
Published through SciTech Connect. 01/01/1977. "la-ur-77-545" " conf-770313-8" Particle accelerator conference, Chicago, IL, USA, 16 Mar 1977. Liska, D.J.; Dauelsberg, L.B.