The ions escaping from the end loss fan of the Mirror Fusion Test Facility (MFTF) neutralize when they hit the surface of the end dome. If the neutrals then bounce back into the oncoming plasma, they are likely to reionize, drawing power from the center of the plasma and reducing the overall electron temperature. In this paper we describe two methods for reducing the reionization rate and a computer code for estimating their effectiveness.
Report Numbers
E 1.99:ucrl-82922 E 1.99: conf-791102-58 conf-791102-58 ucrl-82922
Published through SciTech Connect. 11/01/1979. "ucrl-82922" " conf-791102-58" 8. symposium on engineering problems of fusion research, San Francisco, CA, USA, 13 Nov 1979. Goldner, A.I.; Margolies, D.S.