- Summary
- The imaging properties and design principles for an axisymmetric x-ray microscope using a hyperboloid surface preceding an ellipsoidal reflecting surface are discussed. The results of a design study investigating the off-axis resolution of x-ray microcopes are presented. (MOW)
- Report Numbers
- E 1.99:ucrl-77081
E 1.99: conf-751130-33
conf-751130-33
ucrl-77081 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
10/13/1975.
"ucrl-77081"
" conf-751130-33"
APS meeting, St. Petersburg, FL, USA, 10 Nov 1975.
Boyle, M.J.; Ahlstrom, H.G.; Monjes, J.A.; Palmieri, T.M.
View MARC record | catkey: 14753185