Actions for Effect of hydrogen glow discharge conditioning on Zr
Effect of hydrogen glow discharge conditioning on Zr/Al getter pumps [electronic resource].
- Published
- Princeton, N.J. : Princeton University, 1981.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- Pages: 16 : digital, PDF file
- Additional Creators
- Princeton University and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- Zr/Al bulk getter pumps are presently being considered for use in the Tokamak Fusion Test Reactor (TFTR) to reduce impurities and limit the recycling of hydrogenic species. It is necessary that these pumps not be adversely affected by the hydrogen glow discharge cleaning (GDC) which is planned as part of the routine TFTR vessel wall conditioning. The GDC procedure involves the use of a dc glow discharge with a 400 V bias voltage. The total fluence of hydrogenic ions given to the affected surfaces during a typical conditioning period is 10/sup 18/ cm/sup -2/. We have investigated the effects of typical GDC runs on a getter-pump module containing 25 g of Zr/Al mounted in a 100 liter test stand. Pumping speed, capacity, and regeneration characteristics have been studied after various exposures to GDC.
- Report Numbers
- E 1.99:pppl-1732
pppl-1732 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/01/1981.
"pppl-1732"
Ulrickson, M.; Dylla, H.F.; Cecchi, J.L. - Funding Information