100-kV, 2-ns risetime, dc-coupled probe [electronic resource].
- Published
- Los Alamos, N.M. : Los Alamos National Laboratory, 1981.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- Pages: 8 : digital, PDF file
- Additional Creators
- Los Alamos National Laboratory and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- A high-voltage probe has been designed and constructed; it is unique because it may be used for both high-voltage dc and for transient measurements. The probe is rated at 100-kV dc with a short transient rating of 150-kV peak. System risetime is less than 2 ns. The input impedance is 1000 M..cap omega.. shunted by 13 pF. A distributed RC network providing the desired attenuation is housed in a 25.4-cm-dia cylindrical housing. A 15.2-m length of coaxial cable connects the probe to a termination network at the oscilloscope input. The oscilloscope input impedance must be at least 100 k..cap omega.. to maintain the correct dc attenuation ratio.
- Report Numbers
- E 1.99:la-ur-81-582
E 1.99: conf-810325-3
conf-810325-3
la-ur-81-582 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/01/1981.
"la-ur-81-582"
" conf-810325-3"
Workshop on measurement of electrical quantities in pulsed power systems, Boulder, CO, USA, 2 Mar 1981.
Young, D.; Power, J.; Nunnally, W. - Funding Information
- W-7405-ENG-36
View MARC record | catkey: 14758709