Actions for Calculation of percentile-distance ratios and scaled absorbed-dose distributions for 0. 05- to 30-keV primary electrons [electronic resource].
Calculation of percentile-distance ratios and scaled absorbed-dose distributions for 0. 05- to 30-keV primary electrons [electronic resource].
Published
Washington, D.C. : United States. Dept. of Energy, 1991. Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy.
This document reports the results of computing Berger-type point kernels for 0.05- to 30-keV monoenergetic electrons in a water medium. A detailed-histories Monte Carlo method was used in contrast to the condensed-histories methods used by others. Good agreement with other work was found, over the common energy region. The study was performed at Pacific Northwest Laboratory as an exploratory research project. 8 refs., 10 figs., 2 tabs.