Analytical predictions of liquid and air photovoltaic/thermal flat-plate collector performance [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy, 1980.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description
- Pages: 8 : digital, PDF file
- Additional Creators
- Massachusetts Institute of Technology, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- Two separate one-dimensional analyses have been developed for the prediction of the thermal and electrical performance of both liquid and air flat-plate photovoltaic/thermal (PV/T) collectors. The analyses account for the temperature difference between the primary insolation absorber (the photovoltaic cells) and the secondary absorber (a thermal absorber flat plate). The results of the analyses are compared with test measurements, and therefrom, design recommendations are made to maximize the total energy extracted from the collectors.
- Report Numbers
- E 1.99:coo--4094-89
E 1.99: conf-801102--23
conf-801102--23
coo--4094-89 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
01/01/1980.
"coo--4094-89"
" conf-801102--23"
ASME winter annual meeting, Chicago, IL, USA, 16 Nov 1980.
Raghuraman, P.; Hendrie, S. D. - Funding Information
- AC02-76ET20279
View MARC record | catkey: 14797706