Test and evaluation of a solar-powered laboratory turbocompressor system for building heating and cooling. Final technical report. [Rankine cycle] [electronic resource].
- Published:
- Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1977.
- Physical Description:
- Pages: 124 : digital, PDF file
- Additional Creators:
- United States. Department of Energy. Office of Scientific and Technical Information
- Access Online:
- www.osti.gov
- Summary:
- Extensive testing of an available laboratory Rankine-cycle turbocompressor cooling system was conducted over a range of temperatures consistent with present-day flat-plate and advanced medium-concentration solar collectors and at air- and water-cooled condenser temperature levels. Over 700 hours of testing demonstrated the high performance potential of such systems over a wide range of operational conditions and has provided design guidelines and preliminary specifications for future systems. Minor modifications were made to the laboratory system. These modifications included: (1) demonstration of three tons of cooling at a turbine inlet temperature of about 160 F, (2) efficient operation (i.e., COP of approximately 0.45) at turbine inlet temperatures of 240 F at air-cooled condenser temperatures, and (3) a COP in excess of 0.5 and more than five tons of cooling at system turbine inlet temperature levels of 200 F with water-cooled condenser temperatures. Generally, the test data correlated very well with detailed analytical design and off-design performance projections over the range of operating conditions. These data correlations indicate that the achieved performance levels were limited by mismatching of the existing turbomachinery elements. Data and experience obtained in this program substantiate the judgment that incorporating well-matched turbomachinery, based on existing technology, would result in the achievement of the full potential of a turbocompressor system for both air- and water-cooled operation. Prototype turbocompressor systems can be designed and developed which demonstrate high performance, (i.e., a COP approaching 1.0 and 0.75 for water and air-cooled operation, respectively), versatile operational features, permitting use of different collectors with a range of temperature capability, and potential for significant energy savings when used as solar-powered heating and cooling systems.
- Subject(s):
- Note:
- Published through SciTech Connect., 03/01/1977., "coo/2824-1", " utrc/r-77-952529-1", Biancardi, F.R.; Meader, M.D. Melikian, G.; Landerman, A.M.; Hall, J.B., and United Technologies Research Center, East Hartford, Conn. (USA)
- Funding Information:
- EY-76-C-02-2824
View MARC record | catkey: 14799289