Analysis of the SL-1 Accident Using RELAPS5-3D [electronic resource].
- Published
- Washington, D.C. : United States. Dept. of Energy, 2007.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Additional Creators
- Bettis Atomic Power Laboratory, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- On January 3, 1961, at the National Reactor Testing Station, in Idaho Falls, Idaho, the Stationary Low Power Reactor No. 1 (SL-1) experienced a major nuclear excursion, killing three people, and destroying the reactor core. The SL-1 reactor, a 3 MW{sub t} boiling water reactor, was shut down and undergoing routine maintenance work at the time. This paper presents an analysis of the SL-1 reactor excursion using the RELAP5-3D thermal-hydraulic and nuclear analysis code, with the intent of simulating the accident from the point of reactivity insertion to destruction and vaporization of the fuel. Results are presented, along with a discussion of sensitivity to some reactor and transient parameters (many of the details are only known with a high level of uncertainty).
- Report Numbers
- E 1.99:b-t-3710
b-t-3710 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
11/08/2007.
"b-t-3710"
2007 RELAP5 International User's Seminar.
Francisco, A.D. and Tomlinson, E. T. - Funding Information
- AC11-98PN38206
View MARC record | catkey: 14800194