Decay heat removal by natural convection - the RVACS system [electronic resource].
- Published:
- Washington, D.C. : United States. Dept. of Energy, 1999.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy. - Physical Description:
- 7 pages : digital, PDF file
- Additional Creators:
- Argonne National Laboratory, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Summary:
- In conclusion, this work shows that for sodium coolant the reactor vessel auxiliary cooling system (RVACS) is an effective passive heat removal system if the reactor power does not exceed about 1600 MW(th). Its effectiveness is limited by the effective radiative heat transfer coefficient in the inner gap. In a lead cooled system, economic considerations may impose a lower limit.
- Report Numbers:
- E 1.99:anl/re/cp-99813
anl/re/cp-99813 - Subject(s):
- Other Subject(s):
- Note:
- Published through SciTech Connect.
08/17/1999.
"anl/re/cp-99813"
American Nuclear Society 1999 Winter Meeting, Long Beach, CA (US), 11/14/1999--11/18/1999.
Tzanos, C. P. - Funding Information:
- W-31109-ENG-38
View MARC record | catkey: 14800647