PCRV design and pressure limits for GCFR [electronic resource].
- Published
- Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1979.
- Physical Description
- Pages: 18 : digital, PDF file
- Additional Creators
- United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- This paper presents a review of PCRV design with special emphasis on pressure limitations for large GCFRs. Discussion on major factors affecting PCRV design includes tendon layout requirements; location and arrangement of major components, especially the steam generators, auxiliary heat exchangers, and main and auxiliary circulators; and the balance-of-plant interface requirements. Joint PCRV and containment design efforts are required to evaluate the impact of the horizontal circulator cavity on the PCRV design pressure limitation. Without major departure from current design practice and the benefit of detailed assessment of limiting factors, operating pressures up to 120 bars are found technically feasible.
- Report Numbers
- E 1.99:ga-a-15515
E 1.99: conf-790572-6
conf-790572-6
ga-a-15515 - Subject(s)
- Other Subject(s)
- Note
- Published through SciTech Connect.
07/01/1979.
"ga-a-15515"
" conf-790572-6"
Helium Breeder Associates/US Dept of Energy GCFR technical meeting, San Diego, CA, USA, 30 May 1979.
Koopman, D.C.A.; Chow, G.S.
General Atomic Co., San Diego, CA (USA) - Funding Information
- EY-76-C-03-0167-023