Correlation of Forced-convection Heat-transfer Data for Air Flowing in Smooth Platinum Tube with Long-approach Entrance at High Surface and Inlet-air Temperatures
- Author:
- Desmon, Leland G
- Published:
- November 2, 1950.
- Physical Description:
- 1 electronic document
- Additional Creators:
- Sams, Eldon W
Online Version
- hdl.handle.net , Connect to this object online.
- Restrictions on Access:
- Unclassified, Unlimited, Publicly available.
Free-to-read Unrestricted online access - Summary:
- A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.
- Collection:
- NASA Technical Reports Server (NTRS) Collection.
- Note:
- Document ID: 19930086364.
Accession ID: 93R15654.
NACA-RM-E50H23. - Terms of Use and Reproduction:
- No Copyright.