Transitional flow in thin tubes for space station freedom radiator
- Author
- Loney, Patrick
- Published
- Jan 1, 1995.
- Physical Description
- 1 electronic document
- Additional Creators
- Ibrahim, Mounir B.
Online Version
- hdl.handle.net , Connect to this object online.
- Restrictions on Access
- Unclassified, Unlimited, Publicly available.
Free-to-read Unrestricted online access - Summary
- A two dimensional finite volume method is used to predict the film coefficients in the transitional flow region (laminar or turbulent) for the radiator panel tubes. The code used to perform this analysis is CAST (Computer Aided Simulation of Turbulent Flows). The information gathered from this code is then used to augment a Sinda85 model that predicts overall performance of the radiator. A final comparison is drawn between the results generated with a Sinda85 model using the Sinda85 provided transition region heat transfer correlations and the Sinda85 model using the CAST generated data.
- Other Subject(s)
- Collection
- NASA Technical Reports Server (NTRS) Collection.
- Note
- Document ID: 19950020939.
Accession ID: 95N27360.
NASA. Lewis Research Center, The Sixth Annual Thermal and Fluids Analysis Workshop; p 227-232. - Terms of Use and Reproduction
- No Copyright.
View MARC record | catkey: 15653841