A Mach-Zehnder interferometer is used for optical flow measurements in a transonic wind tunnel. Holographic interferograms are reconstructed by illumination with a He-Ne-laser and viewed by a video camera through wide angle optics. This setup was used for investigating industrial double exposure holograms of truck tires in order to develop methods of automatic recognition of certain manufacturing faults. Automatic input is achieved by a transient recorder digitizing the output of a TV camera and transferring the digitized data to a PDP11-34. Interest centered around sequences of interferograms showing the interaction of vortices with a profile and subsequent emission of sound generated by this process. The objective is the extraction of quantitative data which relates to the emission of noise.