A transmittance model was developed for the 200-2000/cm region for interpretation of high spectral resolution measurements of laboratory absorption and of planetary thermal emission. The high spectral resolution requires transmittances to be computed monochromatically by summing the contribution of individual molecular absorption lines. A magnetic tape atlas of H2O,O3, and CO2 molecular line parameters serves as input to the transmittance model with simple empirical representations used for continuum regions wherever suitable laboratory data exist. The theoretical formulation of the transmittance model and the computational procedures used for the evaluation of the transmittances are discussed. Application is demonstrated of the model to several homogenous path laboratory absorption examples.