Investigation of failure mechanisms in integrated vacuum circuits
- Author
- Rosengreen, A.
- Published
- Aug 1, 1972.
- Physical Description
- 1 electronic document
Online Version
- hdl.handle.net , Connect to this object online.
- Restrictions on Access
- Unclassified, Unlimited, Publicly available.
Free-to-read Unrestricted online access - Summary
- The fabrication techniques of integrated vacuum circuits are described in detail. Data obtained from a specially designed test circuit are presented. The data show that the emission observed in reverse biased devices is due to cross-talk between the devices and can be eliminated by electrostatic shielding. The lifetime of the cathodes has been improved by proper activation techniques. None of the cathodes on life test has shown any sign of failure after more than 3500 hours. Life tests of triodes show a decline of anode current by a factor of two to three after a few days. The current recovers when the large positive anode voltage (100 V) has been removed for a few hours. It is suggested that this is due to trapped charges in the sapphire substrate. Evidence of the presence of such charges is given, and a model of the charge distribution is presented consistent with the measurements. Solution of the problem associated with the decay of triode current may require proper treatment of the sapphire surface and/or changes in the deposition technique of the thin metal films.
- Other Subject(s)
- Collection
- NASA Technical Reports Server (NTRS) Collection.
- Note
- Document ID: 19720020862.
Accession ID: 72N28512.
NASA-CR-112108. - Terms of Use and Reproduction
- No Copyright.