- Wet method reduced exposure by minimizing overall respirable particulate release. Dry method didn't introduce delays for primer/caulk application. Removed caulks came in many forms, from dry powdery to tarry sticky. Varying textures were not sampled or packaged differently. During the course of the project, EPA modified recommended practices to include full containment for exterior caulk removal. Changes are ongoing. Initial recommendations were directed to school buildings. EPA is researching risks due to caulk. Exposure guidance lacking except for 2 of 209 PCB congeners. Work was safely completed on schedule and under budget.