Test conditions and results are reported for various coatings on a 1 percent zirconium columbium alloy at a temperature of 2000 deg F. Molybdenum silicide over molybdenum is most effective coating, tin-aluminum coating is adequately protective, chromium-molybdenum silicides are not protective.