Assessment of RELAP5/MOD2 against a load rejection from 100% to 50% power in the Vandellos II nuclear power plant / prepared by C. Llopis, R. Mendizabal, J. Perez
- Author:
- Llopis, C.
- Published:
- Washington, DC : Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission, June 1993.
- Physical Description:
- 1 online resource (xi, 40 pages) : illustrations
- Additional Creators:
- Mendizabal, R., Pérez, J., and U.S. Nuclear Regulatory Commission. Office of Nuclear Regulatory Research
Access Online
- Series:
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Report Numbers:
- Y 3.N 88:53/0107
ICSP-V 2-R 50-R - Subject(s):
- Note:
- "ICSP-V2-R50-R."
"Asociacion Nuclear de Vandellós (A.N.V.)."
"Consejo de Seguridad Nuclear (C.S.N.)."
"June 1993."
"Prepared as part of the Agreement on Research Participation and Technical Exchange under the International Thermal-Hydraulic Code Assessment and Application Program (ICAP)." - Bibliography Note:
- Includes bibliographical references (pages 13-14).
- Type of Report and Period Covered Note:
- Technical report.
- Funding Information:
- Sponsored by the Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission L2245
View MARC record | catkey: 19177663