Building America Case Study [electronic resource] : Low-Load Space-Conditioning Needs Assessment, Northeast and Mid-Atlantic; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE).
- Published
- Washington, D.C. : United States. Office of the Assistant Secretary of Energy Efficiency and Renewable Energy, 2015.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy - Additional Creators
- National Renewable Energy Laboratory (U.S.), United States. Office of the Assistant Secretary of Energy Efficiency and Renewable Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment - thus facing penalties in system efficiency, comfort, and cost. To bridge the gap between currently available HVAC equipment and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of multifamily buildings and single-family homes market needs. Over the past decade, Steven Winter Associates, Inc. (SWA) has provided certification and consulting services on hundreds of housing projects and has accrued a large pool of data. CARB compiled and analyzed these data to see what the thermal load ranges are in various multifamily apartments and attached single-family home types (duplex and townhouse). In total, design loads from 941 dwellings from SWA's recent multifamily and attached single-family work across the Northeast and Mid-Atlantic were analyzed. Information on the dwelling characteristics, design loads, and the specifications of installed mechanical equipment were analyzed to determine any trends that exist within the dataset. Of the 941 dwellings, CARB found that only 1% had right-sized heating equipment and 6% of the dwellings had right-sized cooling equipment (within 25% or less of design load).
- Report Numbers
- E 1.99:nrel/fs-5500-64207
E 1.99: doe/go-102015-4671
doe/go-102015-4671
nrel/fs-5500-64207 - Subject(s)
- Other Subject(s)
- Residential
- Residential Buildings
- Carb
- Building America
- Low-Load
- Multifamily
- Dwellings
- Swa
- Consortium For Advanced Residential Buildings
- Steven Winter Associates
- All-Electric Hvac Options
- Air-Source Heat Pumps
- Construction Type
- Heating Loads
- Heating Capacity
- Cooling Loads
- Cooling Capacity
- Right-Sized
- Over-Sized
- Hvac
- Space Conditioning Loads
- Equipment Selection
- Note
- Published through SciTech Connect.
07/01/2015.
"nrel/fs-5500-64207"
" doe/go-102015-4671"
View MARC record | catkey: 23762440