2006/07 Field Testing of Cellulose Fiber Insulation Enhanced with Phase Change Material [electronic resource].
- Published:
- Washington, D.C. : United States. Dept. of Energy. Office of Energy Efficiency and Renewable Energy, 2008.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy - Additional Creators:
- Oak Ridge National Laboratory, United States. Department of Energy. Office of Energy Efficiency and Renewable Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Summary:
- Most recent improvements in building envelope technologies suggest that in the near future, residences will be routinely constructed to operate with very low heating and cooling loads. In that light, the application of novel building materials containing active thermal components (e.g., phase change materials [PCMs,] sub-venting, radiant barriers, and integrated hydronic systems) is like a final step in achieving relatively significant heating and cooling energy savings from technological improvements in the building envelope. It is expected that optimized building envelope designs using PCMs for energy storage can effectively bring notable savings in energy consumption and reductions in peak hour power loads. During 2006/07, a research team at Oak Ridge National Laboratory (ORNL) performed a series of laboratory and field tests of several wall and roof assemblies using PCM-enhanced cellulose insulation. This report summarizes the test results from the perspective of energy performance. The ORNL team is working on both inorganic and organic PCMs; this report discusses only paraffinic PCMs. A limited economical analysis also is presented. PCMs have been tested as a thermal mass component in buildings for at least 40 years. Most of the research studies found that PCMs enhanced building energy performance. In the case of the application of organic PCMs, problems such as high initial cost and PCM leaking (surface sweating) have hampered widespread adoption. Paraffinic hydrocarbon PCMs generally performed well, with the exception that they increased the flammability of the building envelope.
- Report Numbers:
- E 1.99:ornl/tm-2007/186
ornl/tm-2007/186 - Subject(s):
- Note:
- Published through SciTech Connect.
12/01/2008.
"ornl/tm-2007/186"
"BT0304030"
"CEBT314"
Kosny, Jan [ORNL]; Yarbrough, David W [ORNL]; Miller, William A [ORNL]; Petrie, Thomas [ORNL]; Childs, Phillip W [ORNL]; Syed, Azam M [ORNL]. - Funding Information: