Actions for RELAP5
RELAP5/MOD2 assessment using semiscale experiments S-NH-1 and S-LH-2 [electronic resource].
- Published
- Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy, 1987.
- Physical Description
- Pages: 69 : digital, PDF file
- Additional Creators
- United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access
- Free-to-read Unrestricted online access
- Summary
- This report presents the results of the RELAP5/MOD2 posttest assessment utilizing two small break loss-of-coolant accident (LOCA) tests (S-NH-1 and S-LH-2) which were performed in the Semiscale Mod-2C facility. Test S-NH-1 was a 0.5% small break LOCA where the high-pressure injection system (HPIS) was inoperable throughout the transient. Test S-LH-2 was a 5% small break LOCA involving a relatively high upper-head-to-downcomer initial bypass flow and nominal emergency core cooling. Through comparisons between data and best-estimate RELAP5 calculations, the capabilities of RELAP5 to calculate the transient phenomena are assessed. For S-NH-1, emphasis was placed on the capability of the code to calculate various operator actions to initiate core heatup in the absence of HPIS. For S-LH-2, the capability of the code to calculate basic small break system response, such as vessel level during loop seal formation and clearing, break uncovery, and primary pressure response following accumulator injection, was assessed. 10 refs., 76 figs., 4 tabs.
- Report Numbers
- E 1.99:nureg/cr-5010
E 1.99: egg-2520
egg-2520
nureg/cr-5010 - Subject(s)
- Note
- Published through SciTech Connect.
10/01/1987.
"nureg/cr-5010"
" egg-2520"
"TI88002541"
Yuann, Ruey-ying; Liang, Kuo-shing; Jacobson, J L.
EG and G Idaho, Inc., Idaho Falls (USA) - Funding Information
- AC07-76ID01570
View MARC record | catkey: 23781928