Initial Evaluation of a New Electromechanical Cooler for Safeguards Applications [electronic resource].
- Published:
- Washington, D.C. : United States. Dept. of Energy, 2002.
Oak Ridge, Tenn. : Distributed by the Office of Scientific and Technical Information, U.S. Dept. of Energy - Additional Creators:
- Oak Ridge National Laboratory, United States. Department of Energy, and United States. Department of Energy. Office of Scientific and Technical Information
Access Online
- Restrictions on Access:
- Free-to-read Unrestricted online access
- Summary:
- The use of liquid nitrogen (LN2) constitutes the current state of the art in cryogenic cooling for high-purity germanium (HPGe) detectors, which are widely used for γ-ray and characteristic X-ray spectroscopy because of their excellent energy discrimination. Use of LN2 requires a liquid nitrogen supply, cumbersome storage tanks and plumbing, and the frequent attention of personnel to be sure that nitrogen levels are sufficient to maintain the detectors at a sufficiently low operating temperature. Safety hazards also are associated with the use of LN2, both because of the potential for severe frostbite on exposure to skin and because it displaces ambient oxygen when it evaporates in closed spaces. Existing electromechanical coolers have, until now, been more expensive to procure and maintain than LN2 systems. Performance and reliability have also been serious issues because of microphonic degradation of photon energy peak resolution and cooler failures due to compressor oil becoming entrained in the refrigerant. This report describes the results of tests of a new HPGe detector cooling technology, the PerkinElmer ORTEC{reg_sign} Products X-Cooler{trademark} that, according to the manufacturer, significantly reduces the lifetime cost of the cooling system without degradation of the output signal. The manufacturer claims to have overcome cost, performance and reliability problems of older-generation electromechanical coolers, but the product has no significant history of use, and this project is the first independent evaluation of its performance for Total cost savings for the DOE and other agencies that use HPGe systems extensively for safeguards monitoring is expected to be quite significant if the new electromechanical cooler technology is shown to be reliable and if performance characteristics indicate its usefulness for this application. The technology also promises to make HPGe monitoring, characterization and detection available for unattended or covert operation and in remote or inaccessible locations where the unavailability of LN2 and signal degradation from existing mechanical coolers prevent its use at the present time.
- Report Numbers:
- E 1.99:ornl/tm-2002/236
ornl/tm-2002/236 - Subject(s):
- Note:
- Published through SciTech Connect.
10/21/2002.
"ornl/tm-2002/236"
Coleman, RL. - Funding Information:
- DE-AC05-00OR22725