EXAMINATION OF COMPONENTS FOR CRUD AND CORROSION 1-B HEAT EXCHANGER HANDHOLE AREA. CORE I, SEED 1. Test Results T-612080
- Published:
- [Place of publication not identified] : [publisher not identified], 1960.
[Oak Ridge, Tennessee] : [U.S. Atomic Energy Commission], 1960. - Physical Description:
- microopaque : positive ; 8 x 13 cm
- Summary:
- The extent and location of corrosion, crud deposits, and defects in the ends of the 1-B heat exchanger after removing the handhole covers were determined. There was no visual evidence of pitting or corrosion inside the ends of the heat exchanger. A radiochemical analysis of a smear sample taken from the inside of number one handhole showed the presence of the following isotopes- Fe/sup 59/, Co/ sup 58/, s1>s, and Zr/sup 95/. A radiation survey performed in four handholes indicated a maximum level of 1 r/hr. (W.L.H.)
- Report Numbers:
- DLCS-1550105
- Other Subject(s):
- Collection:
- U.S. Atomic Energy Commission depository collection.
- Note:
- NSA number: NSA-15-010508
OSTI Identifier 4094936
Research organization: Duquesne Light Co., Shippingport, PA (United States).