In onder to evaluate the fissure tendency of a covered Inconel BP-85 welding electrode, the ductility of weld deposits from this electrode was studied at high temperatures. The results indicate that Inconel BP-85 welds have good hot ductility but lose their ductility completely at 2150 deg F, while wrought Inconel keeps its ductility up to 2400 deg F. (D.L.C.)
U.S. Atomic Energy Commission depository collection.
Note
DOE contract number: W-31-109-ENG-52 NSA number: NSA-14-016998 OSTI Identifier 4135660 Research organization: Knolls Atomic Power Lab., Schenectady, N.Y.